Communication Manager Maintenance Object Repair Procedures<br />

Clock. See TDM-BUS (TDM Bus) for details. A Minor Alarm against the DS1 board is raised, but<br />

every trunk or port of the DS1 board remains in the in-service state.<br />

This test is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MAPD-BD (MAPD Interface Circuit Pack)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

Table 439: Misframe Alarm Inquiry Test (#145) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the test was not received within the allowed time. This may<br />

be due to hyperactivity.<br />

1. Enter display errors<br />

2. Check the Error Log for Error Type 1538. If Error Type 1538 appears<br />

in the error log for this board, see Hyperactive DS1/UDS1 Interface<br />

Circuit Pack/Media Module for the repair procedures. Otherwise,<br />

retry the test at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

ANY FAIL The DS1 board detected errors in the received framing bits pattern. The<br />

Error Code value is the number of misframes detected since the last<br />

misframe alarm inquiry test. Major bit and minor bit error rate (Error<br />

Types 2561 and 2817) errors often accompany misframe alarms.<br />

Clearing the cause of these errors may clear the misframes which are<br />

occurring.<br />

1. Enter list measurement ds1-log location to read the error<br />

seconds measurement.<br />

2. If the DS1/UDS1 circuit pack or media module connects to a T1<br />

network facility or to another switch, see T1 Network Facility<br />

Procedures<br />

3. If the DS1/UDS1 circuit pack or media module connects to a<br />

line-side terminating device such as a PRI terminal adapter, see<br />

Line-side Terminating Device Procedures<br />

1612 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />