Communication Manager Maintenance Object Repair Procedures<br />

Table 170: CO-DS1 Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

3840 (l) Port Audit and Update (#36)<br />

On/Off<br />

Board<br />

Recommended Action<br />

1. CO-DS1 Major alarms may be downgraded to Warning alarms based on the value used in set options.<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 1:<br />

Aux Data 57408: No tip ground is detected on an outgoing call.<br />

Aux Data 57487: PBX could not get “loop close” signal.<br />

If the error occurred on a port of a TN767 DS1 or TN464 UDS1 Interface circuit pack, the<br />

circuit pack detected a hardware fault. These errors will cause the DS1 Dial Tone Test #314<br />

to run and are only considered a problem if the Dial Tone test fails (in which case Error Type<br />

1025 will also show up). In this case, the trunk may be put in the ready-for-service state<br />

(shown as “disconnected” by status), which allows only incoming calls. Run the DS1 Dial<br />

Tone Test #314, and follow the procedures.<br />

c. Error Type 15: software audit error that does not indicate any hardware malfunction. Run<br />

the short test sequence, and investigate associated errors (if any).<br />

d. Error Type 18: the trunk was busied-out and is in an out-of-service state. No calls can be<br />

made on this trunk except Facility Access Test Calls. Release the trunk and retest.<br />

e. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the error, reinsert or replace the circuit pack or media module.<br />

f. Error Type 257: the DS1 Interface circuit pack detects a hardware fault. Aux Data 57392<br />

indicates no external release on PBX disconnect. This alarm will only be raised when the<br />

System-Parameter Country screen has the Base Tone Generator field set to 4 (Italy). This<br />

alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of<br />

service, then the alarm will be upgraded to a MAJOR alarm.<br />

g. Error Type 513: The DS1 Interface circuit pack detects a hardware fault. Aux Data 57393<br />

indicates belated external release on PBX disconnect. This alarm will only be raised when<br />

the System-Parameter Country screen has the Base Tone Generator field set to 4 (Italy).<br />

This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of<br />

service, then the alarm will be upgraded to a MAJOR alarm.<br />

h. Error Type 769: The DS1 Interface circuit pack or media module detects a hardware fault.<br />

The Aux Data contains the following Error Type:—57484, fault is detected on tip/ring.<br />

654 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

2 of 2