VC-LEV (Voice Conditioner Resource Level)<br />

If this outage continues for 15 minutes a MAJOR alarm is raised. To resolve this alarm,<br />

correct the out-of-service problem:<br />

1. See VC-DSPPT (Voice Conditioner DSP Port) and VC-BD (Voice Conditioner Circuit<br />

Pack) to resolve any associated alarms.<br />

2. If a VC-LEV error/alarm exist and none has been raised against VC-BD or VC-DSPPT<br />

MOs, a VC circuit pack may have been removed from service causing the VC-LEV error/<br />

alarm. To resolve a VC-LEV MAJOR alarm, restore the number of VC ports available for<br />

service to be equal to or more than the calculated port capacity. See Resolving VC-LEV<br />

Errors/<strong>Alarms</strong> for details.<br />

Demand test descriptions and error codes<br />

There are no demand tests for VC-LEV.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1417