Communication Manager Maintenance Object Repair Procedures<br />

Error log entries and recommended actions<br />

Table 110: ADX16D-P Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/<br />

Off<br />

Board<br />

Recommended action<br />

0 (a) 0 Any Any Any test port location<br />

1 (b) 40987 WRN OFF<br />

1 (c) 1 to 20 WRN OFF<br />

15 (d) Any<br />

18 (e) 0 busyout port<br />

location<br />

WRN OFF release port location<br />

23 (f) 0 WRN OFF<br />

130 (g) WRN ON test port location<br />

257 (h) 40971<br />

513 (i) Any<br />

1537 (j) 40968 WRN OFF<br />

1793 Voice and Control<br />

Local Loop Test<br />

(#13)<br />

2049 GPP NPE<br />

Crosstalk Test<br />

(#9)<br />

2305 (k) 40967<br />

3840 (l) 40965<br />

3840 (m) 41029<br />

MIN<br />

WRN 1<br />

MIN<br />

WRN1<br />

ON test port location l r 3<br />

ON test port location l r 3<br />

1. Minor alarms may be downgraded to Warning alarms based on the values used in set options.<br />

Notes:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow the recommended procedures<br />

442 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s