Communication Manager Maintenance Object Repair Procedures<br />

Table 519: BRI Layer 3 Query Test (#629) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1113 ABORT The signaling link between the switch and the endpoint or adjunct is<br />

down.<br />

1. Enter test port location long to clear any errors that prevent<br />

establishment of the signaling link.<br />

2. Examine the results of Test #626. If this test aborts or fails, follow the<br />

repair procedure for the Signaling Link Status Test (#626).<br />

3. Escalate problem if BRI Layer 3 Query test continues to abort.<br />

1139 ABORT The PN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the packet bus.<br />

2. After completing step 1, enter test port location long, and<br />

review the results of the BRI Port Local LAN Looparound Test (#618)<br />

to verify the repair.<br />

1144 ABRT The PPN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the PPN’s packet bus.<br />

2. After completing step 1, execute test port PCSSpp long and<br />

review the results of the BRI Port Local LAN Loop Around test<br />

(#618) to verify the repair.<br />