Communication Manager Maintenance Object Repair Procedures<br />

l. Error Type 2561: the PMS Link is physically established, but the protocol has not been<br />

started by the PMS before the protocol timer expires. The PMS Link is NOT torn down. If<br />

this Error Type occurs frequently (more than once a month), advise the customer to call the<br />

vendor of the PMS to check out the PMS device. Once the PMS Link is successfully<br />

established, this error disappears from the Error Log. The PMS should be checked to make<br />

sure that it will attempt to start the protocol according to the PMS/PBX protocol<br />

specifications. No alarm is raised against this error.<br />

m. Error Type 2817: look for the following Aux Data:<br />

10x The PMS violated the application protocol. The first message after a request<br />

to initiate a database exchange was not the start of a database exchange.<br />

The message is processed. If this Error Type with this aux data value occurs<br />

frequently (more than once a month), advise the customer to call the vendor<br />

of the PMS to check out the PMS device. Once the PMS Link is successfully<br />

established, this error disappears from the Error Log.<br />

20x The PMS violated the application protocol. The start of a database exchange<br />

was received in a state in which it was not expected. The message is ignored.<br />

If this Error Type with this Aux data value occurs frequently (more than once a<br />

month), advise the customer to call the vendor of the PMS to check out the<br />

PMS device. Once the PMS Link is successfully established, this error<br />

disappears from the Error Log.<br />

30x The PMS violated the application protocol. The end of a database exchange<br />

was received when no exchange was in progress. The message is ignored. If<br />

this Error Type with this Aux Data value occurs frequently (more than once a<br />

month), advise the customer to call the vendor of the PMS to check out the<br />

PMS device. Once the PMS Link is successfully established, this error<br />

disappears from the Error Log. No alarm is raised against this error.<br />

The PMS should be assessed for adherence to the PMS/PBX protocol specifications.<br />

n. Error Type 3073: the link was taken down by the switch because the threshold for<br />

application protocol violations has been exceeded by the PMS. The protocol never started<br />

and messages were received and/or messages were received in a state in which they were<br />

not expected. (Refer to Error Type 2817 for recommended strategy.)<br />

o. Error Type 3841: link was taken down by the switch because the threshold for link protocol<br />

violations has been exceeded by the PMS. PMS is sending “garbage” to the switch.<br />

1110 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!