Switch Node Interface Reset Test (#761)<br />

Switch Node Interface Reset Test (#761)<br />

This test is destructive.<br />

This test resets the SNI circuit pack using reset board location when an SNI circuit<br />

pack’s location is entered. The SNI is reset via the active SNC circuit pack in the carrier. If the<br />

SNI is connected to an IPSI-connected PN’s EI, the SNI is reset via its IPSI-connected PN’s EI<br />

neighbor. If an SNI with a non IPSI-connected PN’s EI or another SNI as its neighbor cannot be<br />

reset via the active SNC (i.e., if no software communication exists between the active SNC and<br />

the server), an attempt will be made to reset the SNI via its neighbor.<br />

An SNI should be reset instead of reseating the circuit pack. The reset board command<br />

should almost never be used on an SNI. It may be necessary to use reset board if the SNI<br />

circuit pack gets into a mode where it cannot communicate with software.<br />

If an SNI with active errors and alarms is reset, the errors and alarms may take a while to come<br />

back, therefore reset board can mask real problems.<br />

This test runs on SNI-BD (SNI Circuit Pack) and SNI-PEER (SNI Peer Link).<br />

Table 537: Switch Node Interface Reset Test (#761) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this test could not be sent.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2301 ABORT The software timer could not be set before sending the downlink<br />

message necessary to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2302 ABORT Software received incorrect message data from the SNI circuit pack.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2303 ABORT The SNI circuit pack responded that the test requested is invalid.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2304 ABORT SNI circuit pack is not able to run the test requested by software.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />