Communication Manager Maintenance Object Repair Procedures<br />

The test sets up a call to a far-end switch over the trunk to be tested. If a Maintenance/Test<br />

circuit pack does not reside in the system, the test call connection is established over the TDM<br />

Bus of the transmit and receive sides of the ISDN-PRI trunk to a data channel.<br />

If a Maintenance/Test circuit pack does reside in the system, the test call connection is<br />

established over the TDM Bus of the transmit and receive sides of the ISDN-PRI trunk to a<br />

digital trunk testing port on the Maintenance/Test circuit pack. The digital port on a TN771D<br />

Maintenance/Test circuit pack sends a bit pattern to the far end which is echoed back. If the<br />

received pattern matches the pattern that was sent, the test passes. If there are differences, the<br />

test fails.<br />

If a test call is running when scheduled maintenance starts, the green LED is turned off. To<br />

determine whether a test call is still running:<br />

● Enter list isdnpri-testcall and status isdnpri-testcall.<br />

● Check for a lit amber LED on the Maintenance/Test circuit pack.<br />

Synchronous Test Calls<br />

Enter one of the following commands to initiate a synchronous outgoing test call:<br />

● test trunk grp#/mem# long [repeat #]<br />

● test board location long [repeat #]<br />

● test port location long [repeat #]<br />

The duration of the test call is 8.6 seconds for unrestricted (B8ZS) B-Channels and 9.4 seconds<br />

for restricted (ZCS) B-Channels. The test fails if the bit error rate retrieved from the<br />

Maintenance/Test digital port is greater than 0. When this occurs, perform further diagnostics<br />

such as test isdnpri-testcall.<br />

Asynchronous Test Calls<br />

You can start, query, and stop an outgoing test call by using the following commands:<br />

● test isdnpri-testcall grp#/mem# [minutes #]<br />

This command initiates an outgoing ISDN-PRI test call up to 120 minutes. Default times are<br />

as above. Only one trunk per PN can be tested at one time.<br />

● status isdnpri-testcall grp#/mem#<br />

This command displays the progress of the outgoing test call by reporting bit and block error<br />

rates of the tested B-Channel.<br />

● clear isdnpri-testcall grp#/mem#<br />

This command terminates an outgoing test call already in progress. Measurements already<br />

collected are not cleared until the next test call begins.<br />

A PASS of the asynchronous test indicates only that the test call was successfully established.<br />

Enter status and list to get the results of the test.<br />