Table 380: NPE Crosstalk Test (#6) 8 of 8<br />

Error<br />

Code<br />

Test<br />

Result<br />

Conference Circuit Test (#7)<br />

Conference Circuit Test (#7)<br />

Any FAIL The NPE of the tested port is transmitting in error. This causes noisy and<br />

unreliable connections. Clear every off-board problem before replacing the<br />

circuit pack. A TDM-BUS problem is usually the result of a faulty board<br />

connected to the backplane, or bent pins on the backplane.<br />

1. Resolve any of the following errors:<br />

● EXP-PN (Expansion Port Network)<br />

● EXP-INTF (Expansion Interface Circuit Pack),<br />

● RMC-ENV (Power/Fan Sensors)<br />

2. Resolve any TDM-BUS (TDM Bus) errors.<br />

3. Resolve any TONE-BD (Tone-Clock Circuit Pack) or TONE-PT (Tone<br />

Generator) errors.<br />

4. Test the board when the faults from steps 1, 2, and 3 are cleared.<br />

5. If the test fails, replace the circuit pack.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

PASS The port is correctly using its allocated time slots. Investigate user-reported<br />

troubles on this port by using other port tests, examining station and trunk<br />

wiring, examining the station, and ensuring that the station is correctly<br />

translated.<br />

See NO BOARD for the repair procedures.<br />

The Conference Circuit Test verifies that the Network Processing Element (NPE) channel for<br />

the port being tested can correctly perform the conferencing function. The NPE is instructed to<br />

listen to several different tones and conference the tones together. The resulting signal is then<br />

measured by a Tone Detector port. If the level of the tone is within a certain range, the test<br />

passes.<br />

This test runs on the following maintenance objects:<br />

● ADX16A-P (AUDIX Analog Line/Control Link)<br />

● AN-LN-PT (Analog Line Port)<br />

● ANL-16-L (16-Port Analog Line)<br />

8 of 8<br />

Communication Manager Release 5.0 Issue 4 January 2008 1449