Table 526: Stratum-3 Clock Alarm Query Test (#649) 4 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Stratum-3 Clock Alarm Query (#649)<br />

8 FAIL Reference B failed or CI card B failed. This condition usually indicates a<br />

failure of the DS1 reference. However, there may also be a failure of the<br />

CI card to which the reference is connected. The system technician<br />

dispatched to investigate this problem should take a spare CI card in case<br />

the CI card caused the failure.<br />

If you are NOT ON-SITE, use the following procedure:<br />

3. Enter display errors and look for DS1-BD errors. See DS1-BD<br />

(DS1 Interface Circuit Pack) for the recommended repair procedures.<br />

4. If there are no DS1-BD errors or after resolving every DS1-BD error,<br />

enter test synchronization r 4 to see if the alarm still exists.<br />

If every test repetition passes, the alarm no longer exists. Otherwise,<br />

the system technician should be dispatched with a spare CI card to<br />

use the following instructions on-site.<br />

If you are ON-SITE, use the following procedure:<br />

1. Look for a red LED on CI card B (i.e., the right CI card). If there is a<br />

red LED, replace the CI card if a spare is available. If no spare CI is<br />

available on-site, proceed to Step 3.<br />

2. If, after replacing the CI card, the red LED on the new CI card also<br />

lights, proceed to Step 3. Otherwise, enter test synch r 4 to<br />

clear the alarm. If any test repetitions fail, follow the procedure for<br />

those failures.<br />

3. Enter display errors and look for DS1-BD errors. If there are<br />

errors, see DS1-BD (DS1 Interface Circuit Pack) for the<br />

recommended repair procedures. If there are no DS1-BD errors, then<br />

proceed to Step 4.<br />

4. After every DS1-BD error has been resolved or if there are no<br />

DS1-BD errors, enter test synch r 4 to clear the alarm and see if<br />

the alarm still exists. If any test repetitions fail, follow the procedures<br />

for those test failures.<br />

5. Check the DS1 reference B connections to the Stratum-3 clock.<br />

4 of 5<br />

Communication Manager Release 5.0 Issue 4 January 2008 1791