Communication Manager Maintenance Object Repair Procedures<br />

Table 465: 140AY Channel Sanity Inquiry Test (#222) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

2000 ABORT Response to the test was not received within the time allowed.<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

FAIL The test failed. Announcements cannot be played back over this port.<br />

1. Reset the circuit pack with reset board location and then<br />

run this test again. If the test continues to fail, replace the circuit<br />

pack (see Warning).<br />

2. If there are recurring alarms on this port caused by this test failing,<br />

replace the circuit pack even if Step 1 works (see Warning).<br />

WARNING: Replacing<br />

MTP SAT Channel Local Looparound Test (#228)<br />

This test is destructive.<br />

This test checks TN775D on-board circuitry associated with the serial link for the management<br />

terminal connection. This test will not cause the local terminal login to drop, but any data<br />

displayed on the terminal while the test is running will be lost.<br />

The PN’s Maintenance circuit pack has three separate serial interfaces, one for each of the<br />

following:<br />

● Management terminal - tested by Test #228<br />

● Active EI circuit pack - tested by Test #229<br />

● Standby EI circuit pack - tested by Test #229<br />

This test runs on MAINT (PN Maintenance Circuit Pack).<br />

! WARNING:<br />

the circuit pack results in loss of integrated<br />

announcements. Refer to General notes.<br />

PASS Announcements can be played back over this port. User-reported<br />

troubles on this pack should be investigated using other port and circuit<br />

pack tests. Refer to ANN-BD (Announcement circuit pack) for a<br />

description of the circuit pack tests.<br />