Communication Manager Maintenance Object Repair Procedures<br />

i. Error Type 769: the DS1 Interface circuit pack or media module detects a hardware error<br />

on the DS1 tie trunk. This error usually occurs after an occurrence of Error Type 513. The<br />

trunk has received the belated “on-hook” that it has been waiting for from the far-end switch.<br />

The trunk is restored to in-service/idle and can be used for calls. Aux Data 57393 indicates<br />

delayed external release on PBX disconnect. This error can be ignored.<br />

j. Error Type 1793: the DS1 Interface circuit pack or media module is out-of-service. See the<br />

appropriate DS1-BD (DS1 Interface Circuit Pack), UDS1-BD (UDS1 Interface Circuit Pack),<br />

or MG-DS1 (DS1 Interface Media Module) documentation for details.<br />

k. Error Type 2305: reorder message. The trunk could not be seized. This error causes the<br />

Trunk Seizure test (#136) to run and is only a problem if the Seizure test fails (in which case<br />

Error Type 1025 also appears). In this case, the trunk may be put in “Ready-for-Service”<br />

state (shown as “disconnected” by the status command), which allows only incoming calls.<br />

Run the Trunk Seizure test (#136) and follow its procedures.<br />

l. Error Type 2562: retry Failure error. This error is logged only. It is not a hardware failure<br />

and hence does not start any testing or generate any alarms. This error comes from call<br />

processing and is generated when a second attempt (retry) to seize an outgoing trunk fails.<br />

m. Error Type 2817: glare error. This error is logged only. It is not a hardware failure and<br />

hence does not start any testing or generate any alarms. This error is the result of a<br />

simultaneous seizure of a 2-way trunk from both the near and the far ends. Attempt to place<br />

the call again. If the error persists, execute the DS1 Tie Trunk Seizure test (#136) and follow<br />

its procedures.<br />

n. Error Type 3840: Port Audit and Update test (#36) failed due to an internal system error.<br />

Enter status trunk, and verify the status of the trunk. If the trunk is out-of-service, enter<br />

release trunk to put it back to in-service. Retry the test command.<br />