Far-End DS1 Converter Circuit Pack Loopback Test (#788)<br />

Table 545: Far-End DS1 Converter Circuit Pack Loopback Test (#788) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2316 ABORT Fiber link is not administered.<br />

1. Administer the DS1 converter fiber link with add fiber-link and<br />

rerun the test.<br />

2321 ABORT DS1 converter circuit pack is not busied out.<br />

1. Busyout the DS1 converter circuit pack with busyout board.<br />

2332 ABORT With this system configuration (unduplicated PNC), the test cannot run at<br />

the far end when there is only one DS1-FAC available. The link would be<br />

lost, and no test results would be seen at the server. Run the test at the<br />

other end of the DS1C complex.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

FAIL Far-end DS1 converter loopback failed. A problem exists between the<br />

DS1 converter A and the DS1 converter B. See Figure 142: Far-End<br />

DS1 Converter Loopback Configuration.<br />

1. If there are facilities that are not digital-data compatible, busyout the<br />

facilities using busyout ds1-facility.<br />

2. Enter display errors and follow the associated repair<br />

procedures for any on-board DS1C-BD (DS1 Converter Circuit Pack)<br />

errors on this DS1 converter circuit pack and the DS1 converter<br />

circuit pack at the other end of the DS1 converter complex.<br />

3. Enter display errors and follow the associated repair<br />

procedures for any DS1-FAC (DS1 Facility) errors on the DS1<br />

facilities.<br />

4. Check the DS1 Converter Measurements Report to see if there are<br />

facilities with excessive errors. Enter list measurements<br />

ds1-facility summary. If there are facilities with excessive<br />

errors, run the Far-End Internal Loopback test (#797) on those<br />

facilities, and follow repair procedures described for the Far-End<br />

Internal Loopback Test (#797).<br />

5. If the test still fails, replace the DS1 converter circuit pack at the<br />

other end of the DS1 converter complex.<br />

6. If the test still fails, replace this DS1 converter circuit pack.<br />

PASS Transmission through the path of the loopback is successful.<br />