Communication Manager Maintenance Object Repair Procedures<br />

Table 431: DS1 Tie Trunk Seizure Test (#136) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1004 ABORT Far end is seizing the trunk while the test is ongoing. A glare situation is<br />

detected.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port. Enter status trunk to determine the<br />

service state of the port. If the port is in use, wait until the port is idle<br />

before testing.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT Incompatible configuration administered on Trunk Group form.<br />

1. Verify the following fields on the Trunk Group administration form:<br />

a. Is trunk direction incoming only?<br />

b. Is trunk outgoing type either automatic or immediate-start?<br />

c. Is trunk the 24 th port of the DS1 Interface circuit pack or media<br />

module while common control channel signaling is specified?<br />

2. If the trunk has been administered using the above information, this<br />

test should abort.<br />

1018 ABORT The test was disabled by administration. Determine why the test has been<br />

disabled before enabling it.<br />

1. Verify that the Maintenance Test field on the Trunk Group<br />

administration form is n. To enable the test, change the trunk<br />

administration and enter y in the Maintenance Test field.<br />

2. Repeat the test.<br />

1020 ABORT The test did not run due to an already existing error on the specific port or<br />

due to a more general circuit pack or media module error.<br />

1. Examine the error log for existing errors against this port or the circuit<br />

pack or media module and attempt to diagnose the already existing<br />

error.<br />

2. Retry the test.<br />

1040 ABORT The test is invalid for this trunk port because it is administered as an<br />

access endpoint.<br />

1. Enter display port location to verify that this port is<br />

administered as an access endpoint. In this case the test should abort<br />

and no action is necessary.<br />