Communication Manager Maintenance Object Repair Procedures<br />

u. Error Type 3841: this error indicates the RC circuit pack received an inconsistent downlink<br />

message (bad header, bad port number, bad data, etc.) over the Control Channel. This error<br />

is logged only.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

Control Channel Looparound Test (#52) X X ND<br />

RC Hardware Translation Audit (#1317) X X ND<br />

NPE Audit Test (#50) X ND<br />

RC NPE Port Audit Test (#1315) X D<br />

RC NPE Port Loop Test (#1316) X D<br />

RC Tone Loopback Test (#1343) X D<br />

RC NPE Allocation Test (#1336) X X ND<br />

1. D = Destructive; ND = Nondestructive<br />

1162 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

D/ND 1<br />

Clear Error Counters Test (#270) X X ND