BRI-BD (ISDN-BRI Line Circuit Pack)<br />

Error Type 4099: Bad sub-qualifier<br />

Error Type 4100: State inconsistency<br />

Error Type 4101: Inconsistent downlink message<br />

n. Error Type 3843: bad translation RAM detected, but call continues by using another<br />

translation location. This error is not service-affecting. No action is required.<br />

o. Error Type 3999: the circuit pack sent a large number of control channel messages to the<br />

switch in a short period of time.<br />

If Error Type 1538 is also present, the circuit pack was taken out-of-service due to<br />

hyperactivity.<br />

If Error Type 1538 absent, the circuit pack was not taken out-of-service, but has generated<br />

50% of the messages necessary to be considered hyperactive. This may be normal during<br />

heavy traffic periods. If traffic is light, it may indicate a problem with the circuit pack or the<br />

equipment attached to it.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Control Channel Looparound Test (#52) X X ND<br />

NPE Audit Test (#50) X ND<br />

LANBIC Receive Parity Error Counter Test (#595) X ND<br />

1. D = Destructive; ND = Nondestructive<br />