Communication Manager Maintenance Object Repair Procedures<br />

Table 154: BRI-PORT Error Log Entries 2 of 2<br />

Error<br />

Type<br />

1281(g) BRI NPE Crosstalk<br />

(#617)<br />

1537(h) 46210 CRC Error<br />

Counter (#623)<br />

1793(i) BRI Port Local<br />

TDM Looparound<br />

(#619)<br />

3841(j 46208<br />

3842(k) 0<br />

3843(l) 0<br />

3844(m) 46223<br />

3845(n)<br />

3846(o) TEI<br />

3847(p) 0<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level for<br />

BRI-PORT<br />

MIN<br />

WRN1<br />

WRN Any1 OFF<br />

MIN<br />

WRN1<br />

Alarm<br />

Level for<br />

ABRI-PORT<br />

ATT-PORT<br />

LGATE-PT<br />

ATTE-PT<br />

On/Off<br />

Board<br />

Recommended Action<br />

ON test port location l r<br />

2<br />

ON test port location l r<br />

2<br />

1. Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value used in set<br />

options.<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 1: the Level 1 Status Inquiry fails or when the BRI circuit pack detects that Level<br />

1 has been deactivated on the port. Refer to the repair procedures for Level 1 Status Inquiry<br />

Test (#621).<br />

Aux Data blank: the Level 1 Status Inquiry failed.<br />

Aux Data 32773: the BRI-LINE circuit pack detected that Level 1 has been deactivated.<br />

c. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the error, replace or reinsert the circuit pack.<br />

d. Error Type 257: the EPF Status Inquiry fails due to an overcurrent condition or when the<br />

BRI-LINE circuit pack detects that the EPF is in an over current condition. The aux data field<br />

contains one of the following values:<br />

● blank – This indicates that the EPF Status Inquiry failed due to an overcurrent condition.<br />