Demand test descriptions and error codes<br />

TIE-DS1 (DS1 Tie Trunk)<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Note: For<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

NPE Crosstalk Test (#6) X ND<br />

Conference Circuit Test (#7) X ND<br />

DS1 Tie Trunk Seizure Test (#136) X X ND<br />

Port Audit And Update Test (#36) X X ND<br />

1. D = Destructive; ND = Nondestructive<br />

Note:<br />

TN767B vintage 8 or 9 circuit packs, a failure of Test #136 causes a<br />

subsequent failure of Test #7. Test #136 is part of the short sequence and<br />

generates off-board alarms Test #7 is part of the long sequence and generates<br />

on-board alarms. Before entering busyout, release, reset or test board<br />

location long commands, check the vintage number of the circuit pack with<br />

list configuration board location. If it is TN767B vintage 8 or 9, do<br />

not use the above commands until first making sure that Test #136 passes using<br />

test board location. Otherwise, extraneous on-board alarms may be<br />

generated.<br />

D/ND 1<br />