Communication Manager Maintenance Object Repair Procedures<br />

Table 498: Expansion Interface Packet Interface Test (#589) 3 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1139 ABORT The packet bus in the PN where this EI circuit pack resides has a major<br />

alarm against it. This test needs to use the alarmed port network’s packet<br />

bus.<br />

1. Enter display alarms and resolve any PKT-BUS alarms.<br />

2. Retry the command.<br />

1141 ABORT The Packet Interface circuit pack is out of service.<br />

1. See PKT-INT (Packet Interface) for the recommended repair<br />

procedure.<br />

1144 ABORT The PN’s packet bus has a major alarm against it. This test needs to use<br />

the alarmed PN’s packet bus.<br />

1. Enter display alarms and resolve any PKT-BUS alarms.<br />

2. Retry the command.<br />

1394 ABORT The EI circuit pack is out of service and the test cannot be run. This<br />

condition is due to a change in the EI circuit pack’s ability to communicate<br />

with the EI or SNI circuit pack on the other end of the fiber.<br />

1. Run Test #237 and check the Error Log for EXP-INTF Error Type<br />

1281. If Error Type 1281 is present or if Test #237 does not pass, see<br />

the repair procedures for Expansion Interface Neighbor Query Test<br />

(#237).<br />

2. If Test #237 passes, rest the EI pack. Note that this will not be<br />

destructive to the port network where EI circuit pack resides because<br />

it will not be serving as the expansion Archangel if it is not in service.<br />

3. Repeat this test.<br />

1395 ABORT This test cannot be run on an EI circuit pack if it is part of the B-side PNC<br />

and duplicated PNC is not enabled.<br />

1. If this test needs to run on this EI circuit pack, enter change<br />

system-parameters duplication to enable PNC.<br />

2. Enter set pnc lock to prevent the system from doing a PNC<br />

interchange.<br />

3. Repeat this test.<br />