M/T-PKT (Maintenance/Test Packet Bus Port)<br />

3. If the error recurs, replace the Maintenance/Test circuit pack.<br />

When this alarm is active, the amber LED will be in one of three states:<br />

● An unlit amber LED indicates no activity on the Maintenance/Test circuit pack. You can<br />

replace the Maintenance/Test circuit pack.<br />

● If there is an indication of an uncorrectable fault on the packet bus, the amber LED will be<br />

blinking at a rate of 1 Hz. It is OK to replace the Maintenance/Test circuit pack. Ignore the<br />

packet bus error indication, since the Maintenance/Test circuit pack has been determined<br />

to be defective.<br />

● If there is other activity on the Maintenance/Test circuit pack (i.e., ISDN test call), or if<br />

there is an indication of a correctable fault on the packet bus, the amber LED will be on<br />

steady. If there is an ISDN test call in progress, it must be halted using clear<br />

isdnpri-testcall grp#/mem# prior to replacing the circuit pack. Ignore the packet<br />

bus error indication, since the Maintenance/Test circuit pack has been determined to be<br />

defective.<br />

e. Error Type 513: the Packet Bus Port Health Inquiry test failed. Either the packet bus port<br />

has reported a self-test failure, or Communication Manager can communicate with the<br />

Maintenance/Test circuit pack but not with the Maintenance/Test circuit pack packet bus<br />

port. Refer to the description of the Packet Bus Port Health Inquiry Test (#567), and follow<br />

the instructions indicated for the failure code that matches the Aux Data field.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Packet Bus Port Health Inquiry Test (#567) X X ND<br />

Clear Error Counters Test (#270) X ND<br />

1. D = Destructive, ND = Nondestructive<br />