09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EXP-INTF (Expansion Interface Circuit Pack)<br />

Each PN in a direct-connect configuration must be connected to the other PNs through a fiber<br />

link. Each PN has one EI that functions as an Archangel. This EI must be connected with fiber<br />

to an EI. If an EI is functioning as an Archangel (bus master), its amber LED will be flashing at a<br />

rate of 2 seconds on and 200 ms off.<br />

Figure 61: Direct Connect Configuration with Duplicated PNC shows the location of EI circuit<br />

packs in a typical duplicated PNC, direct-connect configuration.<br />

Figure 61: Direct Connect Configuration with Duplicated PNC<br />

Slot #<br />

Slot #<br />

FIBER 1 (A)<br />

E E<br />

I I<br />

In a duplicated PNC there is an A-side and a B-side PNC. Every EI in this diagram is labeled<br />

with an A or a B designating to which PNC it belongs. Note that a PNC’s designation (A or B)<br />

does not relate directly to the carrier where its EIS reside. Again, only one of a PN’s EIs can<br />

function as the Archangel (TDM-bus master). A PN’s EI that is:<br />

● On the active PNC<br />

1<br />

E E<br />

I I<br />

1<br />

2<br />

2<br />

Slot #<br />

Slot #<br />

FIBER 1 (B)<br />

FIBER 3 (B)<br />

EPN<br />

CAB 2<br />

CARRIER B<br />

CARRIER A<br />

FIBER 3 (A)<br />

E E<br />

I I<br />

(B) (B)<br />

2<br />

E E<br />

I I<br />

2<br />

3<br />

(A) (A)<br />

3<br />

PPN<br />

CAB 1<br />

CARRIER C<br />

CARRIER D<br />

FIBER 2 (A)<br />

EPN<br />

CAB 3<br />

CARRIER B<br />

CARRIER A<br />

FIBER 2 (B)<br />

● Logically connected to the server<br />

is the only one that can function in this mode. In normal operation, its amber LED should be<br />

blinking at a rate of 2 seconds on and 200 ms off.<br />

Slot #<br />

Slot #<br />

E E<br />

I I<br />

(B) (B)<br />

(B) (B)<br />

1<br />

E E<br />

I I<br />

(A) (A) (A) (A)<br />

1<br />

2<br />

2<br />

Communication Manager Release 5.0 Issue 4 January 2008 801