● TONE-PT (Tone Generator)<br />

Table 413: Tone Generator Crosstalk Test (#90) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Tone Generator Crosstalk Test (#90)<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1001 ABORT The system was not able to put the tone generation facility in the<br />

appropriate mode to test it.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1002 ABORT The system could not allocate time slots for the test connection. This can<br />

happen when the system is heavily loaded.<br />

1. If the system is not heavily loaded, test the TDM-BUS with<br />

test tdm port-network P.<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore<br />

2000 ABORT Response to the test request was not received within the allowed time.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

FAIL The Tone Generator could be defective. In a port network with more than<br />

one IPSI or Tone-Clock circuit pack, the system will attempt to move the<br />

tone generation function to the alternate one.<br />

1. Test the IPSI or Tone-Clock circuit pack again using<br />

test tone-clock location.<br />

2. If the test fails again, look in the Error Log for Tone Detector circuit<br />

pack errors. If there are Tone Detector circuit pack errors, see the<br />

following Tone Detector documentation to resolve the errors:<br />

● DTMR-PT (Dual-Tone Multifrequency Receiver Port)<br />

● GPTD-PT (General-Purpose Tone Detector Port)<br />

● CLSFY-PT (Call Classifier Port)<br />

● ETR-PT (Enhanced Tone Receiver Port)<br />

3. If there are no Tone Detector circuit pack errors, replace the IPSI or<br />

Tone-Clock circuit pack. See Replacing the IPSI or Tone-Clock Circuit<br />

Pack.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1545