09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table 528: Tie Trunk Seizure Test (#747) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Tie Trunk Dial Test (#747)<br />

1000 ABORT System resources required to run this test are not available. The<br />

trunk may be busy with a valid call.<br />

1. Enter display trunk-group xx to determine the trunk<br />

group/member number of the port.<br />

2. Enter status trunk to determine the service state of the port.<br />

If the service state indicates that the port is in use, wait until the<br />

port is idle before retesting.<br />

3. If the port status is active but the port is idle (no calls), check the<br />

Error Log for Error Type 1025. See the Error Log table for<br />

TIE-TRK (Analog Tie Trunk) for the description of this error and<br />

required actions. The port may be locked up. The far-end may<br />

not be releasing.<br />

4. If the port status is idle, then retry the command at 1-minute<br />

intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the test.<br />

1. Enter display trunk-group xx to determine the trunk<br />

group/member number of the port.<br />

2. Enter status trunk to determine the service state of the port.<br />

If the service state indicates that the port is in use, wait until the<br />

port is idle before retesting.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT This test is not valid for this trunk translation. Must be a wink-start or<br />

delay dial trunk and must be outgoing or 2-way for this test to run.<br />

For the TN2140, the trunk must also be continuous-seize-ack or<br />

discontinuous-seize-ack.<br />

1. Check trunk translation. If it is not a wink-start or delay dial<br />

trunk, this abort message should be ignored.<br />

1018 ABORT Test disabled via administration.<br />

1. Verify that the Maintenance Tests field on the Trunk Group<br />

screen is n. To enable the test, enter change trunk-group x<br />

where x is the number of the trunk group to be tested, and enter<br />

y in the Maintenance Tests field.<br />

2 of 3<br />

Communication Manager Release 5.0 Issue 4 January 2008 1795

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!