<strong>Server</strong> <strong>Alarms</strong><br />

Table 19: SMART <strong>Alarms</strong> 4 of 5<br />

Event<br />

ID<br />

Alarm<br />

Level<br />

Alarm Text, Cause/Description, Recommendation<br />

21 (cont’d) 198 Uncorrectable Sector<br />

Count<br />

199 UltraDMA CRC Error<br />

Count<br />

200 Write Error Rate (Multi<br />

Zone Error Rate<br />

Count of uncorrectable errors when<br />

reading/writing a sector. This error is<br />

critical. An increasing count for this<br />

error may indicate a failing disk drive.<br />

(Samsung, Seagate, IBM (Hitachi),<br />

Fujitsu, Maxtor, Western Digital)<br />

Count of Cyclic Redundancy Check<br />

(CRC) errors during UltraDMA mode<br />

(Samsung, Seagate, IBM (Hitachi),<br />

Fujitsu - select models, Maxtor, Western<br />

Digital - select models)<br />

Total number of errors found when writing<br />

a sector. (Samsung, Seagate, IBM<br />

(Hitachi), Fujitsu, Maxtor, Western Digital)<br />

220 Disk Shift Indicates how much the disk has shifted<br />

(unit of measure unknown). This error is<br />

critical. An increasing value for this<br />

error may indicate a failing disk drive.<br />

(Seagate)<br />

221 G-Sense Error Rate Rate of errors occurring as a result of<br />

impact loads such as dropping the drive<br />

or wrong installation. (Seagate, Hitachi)<br />

222 Loaded Hours Loading on magnetic heads actuator<br />

caused by the general operating time.<br />

223 Load/Unload Retry<br />

Count<br />

Loading on magnetic heads actuator<br />

caused by numerous recurrences of<br />

operations such as reading, recording, or<br />

positioning.<br />

224 Load Friction Loading of magnetic heads actuator<br />

caused by friction in mechanical part of<br />

the store.<br />

226 Load-in Time Total time of loading on the magnetic<br />

heads actuator.<br />

88 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />