Error log entries and recommended actions<br />

Table 177: DID-DS1 Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated<br />

Test<br />

Alarm<br />

Level<br />

On/Off<br />

Board<br />

DID-DS1 (Direct Inward Dial Trunk)<br />

Recommended Action<br />

0 (a) 0 Any Any Any test trunk grp#/mem#<br />

1 (b) Any<br />

15 (c) Any Port Audit and<br />

Update test<br />

(#36)<br />

18 (d) WRN OFF release trunk grp#/mem#<br />

130 (e) WRN ON test trunk grp#/mem#<br />

257 (f) 57474<br />

57473<br />

513 (g) 57392 MAJ<br />

MIN 1<br />

769 (h) 57393 MAJ<br />

MIN 1<br />

1281 Conference<br />

Circuit Test<br />

(#7)<br />

1537 NPE Crosstalk<br />

Test (#6)<br />

MIN<br />

WRN 2<br />

MIN<br />

WRN 2<br />

ON test trunk grp#/mem#<br />

long r 4<br />

ON test trunk grp#/mem#<br />

long r 3<br />

1793 (i) test board location long<br />

2305 (j) 50944 MAJ<br />

MIN 1<br />

3840 (k) Port Audit and<br />

Update (#36)<br />

1. This alarm is raised only when the Base Tone Generator field is 4 (Italy) on the System-Parameter<br />

Country screen. This alarm is a MINOR alarm unless 75% or more trunks in this trunk group are out of<br />

service, when the alarm is upgraded to a MAJOR alarm.<br />

2. Major alarms may be downgraded to Warning alarms based on the value used in set options.<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its recommended procedures.<br />

OFF<br />