Communication Manager Maintenance Object Repair Procedures<br />

DID-TRK (Direct Inward Dial Trunk)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

DID-TRK MAJ 1<br />

MIN<br />

test port location l DID Trunk<br />

WRN None<br />

1. A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by set options<br />

and that at least 75 percent of the trunks in this trunk group are alarmed.<br />

Many trunk problems are caused by incorrect settings of parameters on the trunk group<br />

administration screen. Settings must be compatible with the local environment and with<br />

parameter settings on the far end. Refer to the Administrator Guide for <strong>Avaya</strong> Communication<br />

Manager, 03-300509, for information about how to administer trunks. Refer to your <strong>Avaya</strong><br />

representative for the correct settings for administrable timers and other parameters on a<br />

country-by-country basis.<br />

Direct Inward Dial (DID) trunks coming from the Central Office (CO) allow outside parties to call<br />

directly to an extension in the system. DID Trunk circuit packs include:<br />

DID trunk circuit packs and the MM711 Media Module support eight incoming-only ports. Each<br />

port provides an interface between the 2-wire analog CO line and the 4-wire TDM bus on the<br />

switch.<br />

Not all tests that run on circuit packs are applicable to media modules. These tests will abort<br />

with error code 1412. This error can be ignored.<br />

DID Trunk Operation<br />

TN753 United States<br />

TN2146 Belgium and the Netherlands<br />

TN2139 Italy<br />

TN 436 Australia<br />

TN459 United Kingdom<br />

The DID port receives three to seven digits from the CO that are used to directly connect an<br />

outside caller to the called station without assistance from an attendant. For each call, the CO<br />

switch signals the system by opening and closing individual DID loops (one of the eight ports),<br />

causing the starting or stopping of loop current.<br />