Communication Manager Maintenance Object Repair Procedures<br />

Table 580: CPE Loopback Jack Test (#1212) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

3 FAIL The CPE Loopback Jack test was not set up properly. The framed<br />

3-in-24 test pattern, generated by the DS1 Interface circuit pack and<br />

looped back through the CPE loopback jack, could not be detected<br />

properly by the DS1 circuit pack.<br />

1. Enter test ds1-loop location<br />

cpe-loopback-jack-test-begin<br />

2. If the CPE Loopback test continues to fail, the problem could be with<br />

the DS1 board, the CPE loopback jack equipment, or somewhere in<br />

between. Run test ds1-loop location ds1/<br />

csu-loopback-tests to see if the loopback tests closer to the<br />

DS1 board are successful. If any of those loopback tests fail, follow<br />

the maintenance strategy associated with those.<br />

PASS The CPE Loopback Jack test has successfully began executing. The test<br />

runs until test ds1-loop location end-loopback/span-test is<br />

entered.<br />

1. Enter release board location to release the trunks or ports.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

Far CSU Loopback Test (#1213)<br />

This test is destructive.<br />

For documentation purposes, the term DS1 applies to the following:<br />

DS1 Interface circuit packs<br />

DS1 Interface media modules<br />

UDS1 circuit packs.<br />

The Far CSU Loopback (R-LLB) test causes a loopback at the far-end CSU, and tests all<br />

circuitry and facilities from the local DS1 board to the far-end CSU.<br />

The test is destructive and can only be initiated by entering the command<br />

test ds1-loop location far-csu-loopback-test-begin.<br />