Communication Manager Maintenance Object Repair Procedures<br />

Table 555: Packet Interface Maintenance Looparound Test (#886) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1–5 FAIL Fail Codes 1 - 4:<br />

1 = Did not receive looparound data<br />

2 = Looparound data not correct length<br />

3 = Looparound data did not match<br />

4 = Transmit buffer exhaustion<br />

Either the system could not establish a looparound link from the IPSI’s<br />

Packet Interface module back to itself, or it could not receive data that<br />

was sent on one side of the looparound link.<br />

1. Enter test packet-interface location to retry the test.<br />

If the same Error Code is observed, the system automatically<br />

attempts to reset the Packet Interface and clear the problem.<br />

2. Retry the command. If the test fails, replace the IPSI circuit pack<br />

that has the failing Packet Interface.<br />

3. If the test continues to fail after replacing the IPSI circuit pack,<br />

enter test packet P long.<br />

If any of the tests fail, the fault may be on the packet bus. See<br />

PKT-BUS (Packet Bus) for the recommended repair procedures.<br />

4. If the test continues to fail after the IPSI circuit pack is replaced,<br />

and with no other alarms associated with the packet bus or circuit<br />

packs connected to the packet bus, follow normal escalation<br />

procedures.<br />