Communication Manager Maintenance Object Repair Procedures<br />

Table 607: RC NPE Port Loop Test (#1316) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

1-24 ABORT The Error Code identifies the NPE for which the test aborted. The NPE<br />

is probably being allocated for a call.<br />

1. Enter status radio-controller loc to verify there are no<br />

calls on the RC circuit pack.<br />

2. If not, retry the command at one-minute intervals up to 5 times.<br />

3. If the test continues to abort, escalate the problem.<br />

1-24 FAIL The Error Code identifies the NPE for which the RC NPE Port<br />

Crosstalk test failed.<br />

1. Enter test board loc long repeat 24<br />

2. If any of the tests fail, replace the RC circuit pack.<br />

ANY NO<br />

BOARD<br />

Description / Recommendation<br />

UTAM disablement of radio transmission usually causes this problem.<br />

1. Check the Radio Transmission option. This option can be changed<br />

only at the INADS or higher level.<br />

2. Verify the system is not booting.<br />

3. Enter display radio-controller loc and verify that the RC<br />

is administered.<br />

4. Retry the command at 1-minute intervals up to 5 times.<br />

5. If the test continues to abort, escalate the problem.<br />

PASS All of the NPEs are functioning normally.<br />

RC Hardware Translation Audit (#1317)<br />

This tests validates that the operating parameters which are translated for an RC circuit pack<br />

match those that have been previously downloaded to the circuit pack.<br />

If this audit fails, an error will be logged and a WARNING alarm generated. However, no attempt<br />

will be made to correct the mismatched data by re-downloading to the RC. Instead, the RC<br />

circuit pack needs to be reset to have the operating parameters re-downloaded to the circuit<br />

pack. The RC circuit pack cannot accept operating parameter updates and still remain<br />

in-service.<br />