Idle Time Slot Test (#294)<br />

Idle Time Slot Test (#294)<br />

The Idle Time Slot test detects noisy time slots on the bus and takes them out-of-service. The<br />

Tone Detector circuit is told to listen to idle time slots. If it detects any noise on a time slot, it<br />

returns a failure. At the end of the test, any out-of-service time slots are retested to see if they<br />

are still noisy and are restored to service if they are idle. After every time slot has been tested,<br />

the number of bad time slots are reported in the Error Code field. No more than 220 time slots<br />

will be taken out-of-service on one bus, and no more than 300 will be taken out-of-service on<br />

both buses at one time.<br />

This test runs on TDM-BUS (TDM Bus).<br />

Table 479: Idle Time Slot Test (#294)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

None ABORT Could not allocate the necessary system resources to run this test. For<br />

example, maintenance could be running on the Tone Detector circuit and<br />

it is using the CPTRs.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

1115 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

Any FAIL The Error Code indicates the number of bad time slots that were<br />

detected. The cause of this failure is most likely due to a bad port circuit<br />

pack and not the TDM bus itself.<br />

1. Run the command again.<br />

2. If the error persists, check the Error and Alarm Logs for alarms on the<br />

port network where the faulted TDM bus resides. Also check for<br />

EXP-INTF (Expansion Interface Circuit Pack) alarms associated with<br />

Error Type 1537.<br />

3. Refer to the appropriate circuit pack’s documentation to clear the<br />

circuit pack’s problem.<br />

4. Test the TDM bus again. If the error continues, see TDM-Bus Fault<br />

Detection and Isolation.<br />

PASS Every idle time slot that should be idle is indeed idle. There is no noise on<br />

any of the idle time slots.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1697