Communication Manager Maintenance Object Repair Procedures<br />

DID-DS1 (Direct Inward Dial Trunk)<br />

MO Name in Log Alarm<br />

Level<br />

DID-DS1 MAJ 1<br />

MIN<br />

Initial Command to Run Full Name of MO<br />

test trunk grp#/mem# long Direct Inward Dial Trunk<br />

WRN test trunk grp#/mem#<br />

1. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by set options<br />

and that at least 75 percent of the trunks in this trunk group are alarmed.<br />

The DID-DS1 trunk provides a digital Direct Inward Dial (DID) trunk from a CO switch to the<br />

system through a DS1 link. A 24-channel DS1 link can support up to 24 DID-DS1 trunk calls<br />

simultaneously. A 32-channel link can support up to 30.<br />

A DID-DS1 trunk can be used for digitized voice and data communications with DS1 signaling<br />

mode (for example, common-channel signaling). The TN767 and TN464 circuit packs and the<br />

DS1 Interface Media Module support wink-start and immediate-start trunks and Communication<br />

Manager signaling. Throughout this section, the term DS1 applies to all. For more information,<br />

see one of the following maintenance objects:<br />

Circuit Pack/Media Module Maintenance<br />

Object<br />

TN767 DS1 Interface Circuit Pack DS1-BD<br />

TN464 UDS1 Interface Circuit Pack UDS1-BD<br />

DS1 Interface Media Module MG-DS1<br />

Not all tests that run on circuit packs are applicable to media modules. These tests will abort<br />

with error code 1412. This error can be ignored.<br />

Two trunk service states are specified in the DID-DS1 trunk maintenance:<br />

out-of-service The trunk is in a deactivated state and cannot be used for<br />

incoming calls.<br />

in-service The trunk is in an activated state and can be used for<br />

incoming calls.<br />

If a DS1 is out-of-service, every trunk on the circuit pack or media module is put into the<br />

out-of-service state, and a Warning alarm is raised.<br />