Communication Manager Maintenance Object Repair Procedures<br />

Table 382: GPP NPE Crosstalk Test (#9) 2 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this test are not available or the port<br />

may be busy with a valid call.<br />

ADX8D-PT and ADX16D-P:<br />

1. Enter display port location to determine the extension of the<br />

port.<br />

2. Enter status station location to determine the service state<br />

of the port. If the port is in use, wait until it is idle before retesting.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

DIG-LINE and E-DIG-ST:<br />

1. Enter display port location to determine the station<br />

extension or attendant number of the port.<br />

2. Enter status station extension or status attendant<br />

location to determine the service state of the port. If the port is in<br />

use, wait until it is idle before testing. Attendants are always in use<br />

(off-hook) if the handset is plugged in and the port is not busied out.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

M/T-ANL:<br />

1. The port may be in use on a valid ATMS trunk call. Retry the<br />

command at 1-minute intervals up to 3 times.<br />

M/T-DIG:<br />

1. Enter list isdnpri-testcall to determine if the port is in use<br />

(listed in the M/T Port column). If so, wait for the test call to finish as<br />

indicated in the Start Time and Duration fields, or abort the test call<br />

with clear isdnpri-testcall grp#/mem#, where grp#/<br />

mem# is determined from the B-Channel field of list<br />

isdnpri-testcall.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

PDMODULE and TDMODULE:<br />

1. Enter display port location to determine the extension of the<br />

port.<br />

2. Enter status data-module extension to determine the<br />

service state of the port. If the port is in use, wait until it is idle before<br />

retesting.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1458 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

2 of 6