Communication Manager Maintenance Object Repair Procedures<br />

m. Error Type 769, Aux Data 2: This error only applies to TN574 DS1 converter circuit packs.<br />

If the alarm is on board, then a minor hardware problem has occurred that affects only<br />

circuit data being transmitted from the DS1 converter circuit pack. Replace the DS1<br />

converter circuit pack.<br />

If the alarm is off board, then either a minor hardware problem has occurred that affects only<br />

circuit data being transmitted from the DS1 converter circuit pack or a good clock signal<br />

cannot be recovered from the fiber channel.<br />

1. Enter display errors and follow the associated repair procedures for any SYNC<br />

(Port Network Synchronization), TDM-CLK (TDM Bus Clock), and SNC-BD (Switch Node<br />

Clock Circuit Pack) errors.<br />

2. Enter display errors and follow the associated repair procedures for any EXP-INTF<br />

(Expansion Interface Circuit Pack), SNI-BD (SNI Circuit Pack), and FIBER-LK (Fiber<br />

Link)errors.<br />

3. If the problem persists, replace the DS1 converter circuit pack.<br />

n. Error Type 769, Aux Data 3: This error only applies to TN574 DS1 converter circuit packs.<br />

If the alarm is on board, then a minor hardware problem has occurred that affects only<br />

packet data being received from the DS1 converter circuit pack. Replace the DS1 converter<br />

circuit pack.<br />

If the alarm is off board, then either a minor hardware problem has occurred that affects only<br />

packet data being received from the DS1 converter circuit pack or corrupted packets are<br />

being received from the packet facility.<br />

1. Enter display errors and follow the associated repair procedures for any EXP-INTF<br />

(Expansion Interface Circuit Pack), SNI-BD (SNI Circuit Pack), and DS1-FAC (DS1<br />

Facility) errors.<br />

2. If the problem persists enter display errors and follow the associated repair<br />

procedures for any SYNC (Port Network Synchronization), TDM-CLK (TDM Bus Clock),<br />

and SNC-BD (Switch Node Clock Circuit Pack) errors.<br />

3. If the problem still persists, replace the DS1 converter circuit pack.<br />

o. Error Type 769, Aux Data 5: If the alarm is on board, then a minor FOI transmit error<br />

occurred that affects data transmitted from the fiber link to the DS1 facility. Replace the DS1<br />

converter circuit pack.<br />

If the alarm is off board, then either a minor FOI transmit error occurred that affects data<br />

transmitted from the fiber link to the DS1 facility. or corrupted packets are being received<br />

from the packet facility.<br />

1. Enter display errors and follow the associated repair procedures for any EXP-INTF<br />

(Expansion Interface Circuit Pack), SNI-BD (SNI Circuit Pack), and DS1-FAC (DS1<br />

Facility) errors.<br />

2. If the problem persists enter display errors and follow the associated repair<br />

procedures for any SYNC (Port Network Synchronization), TDM-CLK (TDM Bus Clock),<br />

and SNC-BD (Switch Node Clock Circuit Pack) errors.<br />

766 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s