Figure 99: Fan Removal<br />

Error log entries and recommended actions<br />

Table 321: RMC-ENV Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

RMC-ENV (Power/Fan Sensors)<br />

On/Off<br />

Board<br />

Recommended<br />

Action<br />

0 (a) 0 Any Any Any test environment<br />

1 (b) Any Cabinet Temperature Query test<br />

(#122)<br />

MAJ ON test environment<br />

Notes:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its procedures.<br />

b. Error Type 1: the power-/fan-status lead indicates that a G600 media gateway’s power<br />

supply has detected an alarm condition. The condition can be caused by the failure of any<br />

fan’s or any power supply’s output. If more than one G600 exists, every power-/fan-status<br />

lead is tied together. (The fan and power lead is an O-ring of every cabinet’s status lead.)<br />

Since an error condition on a fan’s or power supply’s output could be the result of a<br />

temporary overload (e.g., during board insertion) or caused by the equipment’s location<br />

(e.g., fan blockage), a single event may be an anomaly that eventually clears. However, a<br />

repeating condition causes a major alarm.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1175