Table 133: Error type 1281 Aux Data and repair procedures 1 of 3<br />

Aux<br />

Data<br />

Alarm<br />

Description<br />

15 SYSCLOCK<br />

failed<br />

16 Loss of Signal:<br />

LOS<br />

17 Loss of Frame:<br />

LOF<br />

18 Multiplexer<br />

Section Alarm<br />

Indication<br />

Signal:<br />

MS_AIS<br />

Repair procedure<br />

ATM-EI (Expansion Interface Circuit Pack)<br />

The board is not locked to the TDM backplane clock signal. This is<br />

probably due to a Tone-Clock problem.<br />

1. Check for TDM-BUS or TONE-BD errors in the Error Log.<br />

2. If no other problems are present, reset the circuit pack (reset<br />

board location)<br />

The fiber is not connected properly to the ATM-EI board or ATM<br />

switch (or to the multiplexer section [MUX] if present).It is possible<br />

that the board transceivers are not functioning properly.<br />

1. Run test board location.<br />

2. If Test #1259 fails, connect a fiber back-to-back in a looped<br />

mode (one strand of fiber connecting the transmit transceiver to<br />

the receive transceiver of the board) and see if the amber LED<br />

flash goes away. If it does, the problem is off-board.<br />

3. If the amber LED continues to flash, replace the circuit pack.<br />

The fiber signal cannot obtain or maintain STM-1/OC-3 framing.<br />

1. Try to move the fiber on the ATM switch side to a different port.<br />

This could require administration on the ATM switch.<br />

2. If the problem persists, reset the circuit pack (reset board<br />

location).<br />

There is a major problem on the far end (between multiplexer<br />

section [MUX] and the switch) that prohibits the circuit pack from<br />

sending a valid signal.<br />

1. See if the ports at the MUX and/or the ATM switch are<br />

connected snugly.<br />

2. Run test board location.<br />

3. If Test #1259 fails with Error Code 18, connect a fiber<br />

back-to-back in a looped mode (one strand of fiber connecting<br />

the transmit transceiver to the receive transceiver of the board)<br />

and see if the amber LED flash goes away.<br />

4. If it does, the problem is off-board.<br />

5. If the amber LED continues to flash, replace the circuit pack; if<br />

the error persists, escalate the problem.<br />

1 of 3<br />