Communication Manager Maintenance Object Repair Procedures<br />

Table 408: Tie Trunk Seizure Test (#73) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this test are not available. The<br />

trunk may be busy with a valid call.<br />

1. Enter display trunk-group xx to determine the trunk<br />

group/member number of the port.<br />

2. Enter status trunk to determine the service state of the port.<br />

If the service state indicates that the port is in use, wait until the<br />

port is idle before retesting.<br />

3. If the port status is active but the port is idle (no calls), then<br />

check the Error Log for Error Type 1025. See the Error Log table<br />

for a description of Error Type 1025 for this maintenance object.<br />

The port may be locked up. The far-end may not be releasing.<br />

4. If the port status is idle, then retry the command at 1-minute<br />

intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the test.<br />

1. Enter display trunk-group xx to determine the trunk<br />

group/member number of the port.<br />

2. Enter status trunk to determine the service state of the port.<br />

If the service state indicates that the port is in use, wait until the<br />

port is idle before retesting.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT This test is not valid for this trunk translation. The trunk must be a<br />

wink-start or delay dial trunk and must be outgoing or 2-way for this<br />

test to run. For the TN2140, the trunk must also be<br />

continuous-seize-ack or discontinuous-seize-ack.<br />

1. Check trunk translation. If it is not a wink-start or delay dial<br />

trunk, this abort message should be ignored.<br />

1018 ABORT Test is disabled by administration.<br />

1. Verify that the Maintenance Tests field on the Trunk Group<br />

screen is n. To enable the test, enter change trunk-group x<br />

where x is the number of the trunk group to be tested, and enter<br />

y in the Maintenance Tests field.<br />

1534 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />