Battery and Power Supply Query Test (#5)<br />

Battery and Power Supply Query Test (#5)<br />

The Battery and Power Supply Query Test queries the PN’s Maintenance circuit pack for the<br />

status of the battery pack and battery charger, then reports the result. In a DC-powered system,<br />

this test should never fail. On AC-powered systems, the test turns the battery charger status<br />

LED on and off to determine if the battery charger is connected.<br />

Depending on the cabinet type, this test runs on the following maintenance objects:<br />

● AC-POWER<br />

● CABINET (Cabinet Sensors)<br />

● CARR-POW (Carrier Power Supply)<br />

● DC-POWER (Single-Carrier Cabinet Environment)<br />

● EMG-XFER (Emergency Transfer)<br />

● EXT-DEV (External Device Alarm)<br />

● POWER<br />

● RMC-ENV (Power/Fan Sensors)<br />

● SER-BUS (Serial Communication Bus)<br />

Table 379: Battery and Power Supply Query Test (#5) 1 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this test are not available.<br />