09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

c. Error Type 257: An endpoint is not responding to the service state query message sent to<br />

the adjunct or to the endpoint. This error causes an alarm to be raised. The alarm is retired<br />

when the switch receives a response to the service state query to the endpoint or to the<br />

adjunct.<br />

When this error occurs for an ASAI adjunct, the Aux Data field indicates the state of the<br />

ASAI link and whether an invalid response or no response was received to the query from<br />

the switch, as shown in the following table:<br />

Aux<br />

Data<br />

ASAI Link State Error<br />

102 13-restarting No response to RESTART message<br />

104 13-restarting Invalid response to RESTART message<br />

152 13-restarted No response to layer-3 query<br />

154 13-restarted Invalid response to layer-3 query<br />

202 13-established No response to layer-3 query<br />

204 13-established Invalid response to layer-3 query<br />

See Maintenance SAT Commands in Maintenance Commands Reference (03-300431) for<br />

an explanation of the ASAI link states.<br />

For ASAI or <strong>Avaya</strong> adjuncts, the switch queries the adjunct every two minutes. The Layer 3<br />

Query test is not executed for ASAI or <strong>Avaya</strong> adjuncts through a command entered from the<br />

management terminal. While alarmed for this error, the switch takes the associated port<br />

out-of-service for five seconds every 15 minutes. This action attempts to stimulate recovery<br />

actions to be taken by the adjunct.<br />

When this error occurs for an ASAI or <strong>Avaya</strong> adjunct, the service technician should:<br />

1. Execute test station extension and perform the associated repair procedures.<br />

2. Check the health of the adjunct by following the recommended repair procedures of the<br />

manufacturer of the adjunct if the preceding step does not resolve the problem.<br />

d. Error Type 351: logged against an ASAI endpoint when the adjunct asks the switch to<br />

suspend maintenance on the ASAI endpoint. Clear with busyout and release of the ASAI<br />

station.<br />

e. Error Type 513: the endpoint sent more messages than the switch could handle. The<br />

switch suspends the reception of messages from the endpoint for a short period of time.<br />

There is no repair procedure for this error. If the condition persists, replace the endpoint.<br />

f. Error Type 769: an ASAI endpoint’s associated signaling link has too much traffic related to<br />

link establishment. This occurs when the signaling link is alternating between assigned and<br />

established states. If this problem persists, replace the endpoint.<br />

484 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s