Communication Manager Maintenance Object Repair Procedures<br />

Table 498: Expansion Interface Packet Interface Test (#589) 5 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

ANY FAIL The transmitted data packet was not received correctly by the Packet<br />

Interface circuit pack. The failure may be in the EI under test, the DS1<br />

converter circuit packs, or the intervening Center Stage components.<br />

1. Test the Packet Interface circuit with test packet-interface CS<br />

where “C” is the IPSI’s carrier in a high- or critical-reliability system,<br />

and “S” is the slot number where the IPSI’s Packet Interface resides.<br />

If the Packet Interface circuit fails any tests, see PKT-INT (Packet<br />

Interface).<br />

2. If the EI under test resides in a high-reliability system’s PN,<br />

(2 PN-to-CSS fibers in an unduplicated PNC), run the short test<br />

sequence on both of the PN’s EI boards, and follow procedures for<br />

Test #589.<br />

3. Enter display errors and resolve any PKT-BUS errors.<br />

4. Perform the Fiber link fault isolation in Chapter 4: General<br />

troubleshooting in Maintenance Procedures (03-300432).<br />

PASS Although this test has passed, there may be related problems on other<br />

EIs used in connectivity to and from this EI. Software may have<br />

conducted tests on these other components and determined that this<br />

board was functioning properly and any problems were probably due to a<br />

problem with some other connectivity component. Check the error and<br />

alarm logs for problems with other EI circuit packs and resolve these<br />

errors.<br />

1. Refer to other EI board tests if the link is not functioning correctly.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

1734 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

5 of 5