BRI-BD (ISDN-BRI Line Circuit Pack)<br />

BRI-BD (ISDN-BRI Line Circuit Pack)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

BRI-BD MAJ<br />

MIN<br />

WNR<br />

LGATE-BD MAJ<br />

MIN<br />

WRN<br />

(See Caution)<br />

test board location l ISDN-BRI Line circuit pack<br />

test board location l LAN Gateway<br />

test board location<br />

! CAUTION:<br />

CAUTION: A detailed flowchart for isolating and resolving Packet Bus faults is included in<br />

Isolating and repairing packet-bus faults in Maintenance Procedures<br />

(03-300432). This flowchart, along with the other information presented in the<br />

chapter, can help in resolving problems that involve more than a single station or<br />

circuit pack. Whenever the repair procedures for this Maintenance Object refer to<br />

Packet Bus and/or Packet Control maintenance, be sure to see Isolating and<br />

repairing packet-bus faults. See also PKT-BUS (Packet Bus) for repair<br />

procedures.<br />

Error log entries and tests also apply to LGATE-BD.<br />

This section relates to the TN556 ISDN BRI, TN2198 ISDN BRIU, and TN2208 LAN Gateway<br />

(LGATE) Multifunction (MFB) circuit packs.<br />

The TN2208 LGATE MFB provides the system with the interface to Adjunct-Switch Application<br />

Interface (ASAI) and <strong>Avaya</strong> adjuncts (for example, CONVERSANT ® Voice System). This circuit<br />

pack contains 12 ports for line circuit interface (although only 8 are usable by the switch), each<br />

of which operates with two B channels and one D-Channel. In this context, the term “ISDN-BRI<br />

port” is used to refer to ports on the TN2208 MFB circuit pack that are connected to ASAI or<br />

<strong>Avaya</strong> adjuncts. The TN2208 LGATE MFB is handled by the switch software as if it is an<br />

ISDN-BRI compatible board, and every maintenance action referring to ASAI and <strong>Avaya</strong> adjunct<br />

links in this section applies.<br />

The TN556, TN2198, and TN2208 ISDN-BRI Lines are packet port circuit packs that provides<br />

access to ISDN-BRI endpoints. The ISDN-BRI Line circuit packs supports 12 ports, each of<br />

which provides access to ISDN stations. Voice and circuit-switched data from the ISDN stations<br />

are carried on the Time Division Multiplex (TDM) Bus. Signaling is carried over the packet bus.<br />

Communication Manager Release 5.0 Issue 4 January 2008 585