Demand test descriptions and error codes<br />

MODEM-PT (Modem Pool Port)<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Note: The<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

Modem Pool NPE Crosstalk Test (#96) X D<br />

Modem Pool Conference Test (#97) X D<br />

Modem Pool Conversion Resource Looparound Test (#98) X X ND<br />

Modem Pool Audit Test (#99) X X ND<br />

1. D = Destructive, ND = Nondestructive<br />

Note:<br />

tests do not apply to Combined Modem Pool conversion resources. The<br />

standard Digital Line and/or Analog Line port tests are run on the ports<br />

associated with the Combined Modem Pool. Consult the test descriptions for<br />

those MOs when repairing Combined Modem Pool arrangements.<br />

D/ND 1<br />

Communication Manager Release 5.0 Issue 4 January 2008 1039