Communication Manager Maintenance Object Repair Procedures<br />

For BRI endpoints, each B-Channel may support voice or circuit-switched data and may be<br />

circuit-switched simultaneously. The B-Channels are not used on ports connected to ASAI or<br />

<strong>Avaya</strong> adjuncts. The D-Channel is used for conveying signaling between the switch and a BRI<br />

endpoint(s), ASAI or <strong>Avaya</strong> adjunct. Each ISDN-BRI D-Channel is connected to the switch<br />

processor and the ISDN-BRI port through the packet bus.<br />

ISDN-BRI endpoints are available in various configurations. Every endpoint requires the<br />

D-Channel to convey signaling information to the switch. Only one B-Channel is required for a<br />

voice-only set or a stand-alone data module (BRI-DAT). A voice and data-capable set requires<br />

both B-Channels (one for voice and one for data). Therefore, each TN556 or TN2198 port can<br />

support either two voice-only sets, two stand-alone data modules (BRI-DAT), or one voice and<br />

data-capable set. Only a single ASAI or <strong>Avaya</strong> adjunct may be connected to an ISDN-BRI port.<br />

Multiple adjuncts per line are not supported.<br />

Figure 39: ISDN-BRI Port Interactions illustrates the physical connection (solid line) between<br />

an ISDN-BRI port and its associated ISDN-BRI set(s). Each physical connection allows for two<br />

B-Channels and one D-Channel. Each ISDN-BRI circuit pack can support up to 12 of these<br />

physical connections to different voice and voice/data sets or ASAI or <strong>Avaya</strong> adjuncts. On a<br />

TN2198 each ISDN-BRI circuit pack can support up to 12 physical connections to a NT1 which<br />

in turn connects to 2 terminals.<br />

This section covers the maintenance documentation for ISDN-BRI ports. Some of the results of<br />

maintenance testing of ISDN-BRI ports may be affected by the health of the ISDN-BRI Line<br />

circuit pack (BRI-BD), BRI endpoint (BRI-SET), or ASAI adjunct (ASAI-ADJ/LGATE-ADJ/<br />

LGATE-AJ) or <strong>Avaya</strong> adjunct (ATT-ADJ/ATTE-AJ). These interactions should be kept in mind<br />

when investigating the cause of ISDN-BRI port problems. For more information about the circuit<br />

pack, see:<br />

● BRI-BD (ISDN-BRI Line Circuit Pack)<br />

● BRI-SET, Various Adjuncts<br />

and for more information about its endpoints, see:<br />

● ASAI-ADJ (ASAI Adjunct)<br />

● ATT-ADJ (<strong>Avaya</strong> Adjunct)<br />

● LGATE-AJ (Ethernet ASAI Endpoint)<br />

592 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s