Table 603: ATM Remote Layer 3 Query Test (#1291) 2 of 2<br />

Error<br />

Code<br />

2500<br />

none<br />

Test<br />

Result<br />

Description / Recommendation<br />

ATM Board DSP Test (#1293)<br />

ATM Board DSP Test (#1293)<br />

ABORT Internal system error or administration problem<br />

1. Determine whether any B-Channels are administered.<br />

2. If there are none, this is a normal ABORT since this test cannot run<br />

unless at least one B-Channel is administered.<br />

3. If at least one B-Channel is administered, there is an internal system<br />

error. Retry the command at 1-minute intervals up to 5 times.<br />

FAIL Internal system error<br />

1. See description of ABORT with Error Code 2500.<br />

PASS A message was sent to the far-end switch or terminal adapter. The ISDN<br />

PRI specification allows up to 2 minutes for a reply.<br />

1. Check the Error Log for ATM-SGRP errors of type 2305 for evidence<br />

of a Remote Layer 3 Query failure.<br />

2. If no new errors were logged since this test was run, this switch and<br />

the far-end switch can exchange call control messages.<br />

3. If there is still a problem with a particular ATM trunk, busyout the trunk<br />

and run the long test sequence. Note the results of ISDN Test Call<br />

Test (#258).<br />

This test checks the board’s interface to the TDM bus and the functions of all 24 on-board DSPs<br />

(Digital Signal Processors). There are three functional types of DSPs:<br />

● talkers – put data on the TDM bus<br />

● listeners – take data off the TDM bus<br />

● echo cancellers – filter out echoes of the main transmission<br />

If the test fails for every DSP, a MAJOR alarm is raised against the board.<br />

If the test fails for one or more DSPs, a MINOR alarm is raised.<br />

If a DSP is busy, the test for that particular DSP is considered passed.<br />

2 of 2<br />