Communication Manager Maintenance Object Repair Procedures<br />

Table 470: Expansion Interface Local Looparound Test (#240) 4 of 4<br />

Expansion Interface 2-Way Transmission Test (#241)<br />

Note: The<br />

Error<br />

Code<br />

Test<br />

Result<br />

1 FAIL Loopback on TDM Bus A failed. Loopback on TDM Bus B passed.<br />

2 Loopback on TDM Bus B failed. Loopback on TDM Bus A passed.<br />

3 Loopback on both TDM Buses failed.<br />

12 Loopback on TDM Bus B failed. Loopback on TDM Bus A aborted<br />

because the system could not allocate time slots.<br />

21 Loopback on TDM Bus A failed. Loopback on TDM Bus B aborted<br />

because the system could not allocate time slots.<br />

None The test tone was not detected correctly after being looped through the<br />

EI circuit pack.<br />

1. Enter display errors and check if Error Type 2305 has been<br />

logged against the EI circuit pack in the last 5 minutes. If so, this test<br />

could have failed due to the associated slips. First resolve the 2305<br />

error, then repeat the test.<br />

2. Run the tests for the active Tone-Clock on the PN that contains the<br />

indicted EI circuit pack to verify that dial-tone is supplied.<br />

3. If the tone-clock is healthy, repeat the short test on the EI board.<br />

4. If this test continues to fail, replace the EI circuit pack.<br />

PASS Test tone was correctly detected after internal EI loopback on both TDM<br />

buses.<br />

1. Refer to other EI circuit pack tests if the links between this EI circuit<br />

pack and the EI or SNI circuit pack on the other end of the fiber is<br />

not functioning correctly.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

Note:<br />

term EI applies to both the Expansion Interface (EI) and ATM Expansion<br />

Interface (ATM-EI) boards.<br />