Communication Manager Maintenance Object Repair Procedures<br />

Table 495: Maintenance/Test Circuit Pack Query Test (#572) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2077 ABORT The Maintenance/Test Circuit Pack Query located more than one<br />

Maintenance/Test packet bus port in the PN.<br />

This is an internal system error and should not occur. Escalate the<br />

problem, but also attempt the following work-around steps.<br />

1. Remove every Maintenance/Test circuit pack from the PN.<br />

2. Insert one Maintenance/Test circuit pack. There should not be more<br />

than one in a PN.<br />

3. Re-enter the test command.<br />

2100 ABORT Could not allocate all necessary resources to perform this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2500 ABORT An internal operation failed. The test could not be completed.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />