Table 397: NPE Audit Test (#50) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

1019 ABORT A test was already running on the port.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

Ringing Application Test (#51)<br />

Ringing Application Test (#51)<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />

2030 ABORT EPN is down.<br />

FAIL Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

PASS The circuit pack’s SCOTCH-NPE chip has been updated.<br />

NO<br />

BOARD<br />

EXTRA<br />

BD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

Certain circuit packs have limitations on how many circuit packs can be in<br />

the system or port network such as the Maintenance/Test circuit pack<br />

(TN771B or TN771C), the Tone Detector circuit pack (TN748B, TN748C or<br />

TN748D) and the Call Classifier (TN744). The Maintenance/Test circuit<br />

pack allows only one circuit pack per port network. The Tone Detector and<br />

Call Classifier allow only 10 circuit packs in each system. All additional<br />

circuit packs will return EXTRA-BD and should be removed.<br />

The Ringing Application Test checks the ringing application circuitry common to every port on<br />

an Analog Line circuit pack. This test runs on the following maintenance objects:<br />

● MG-ANA (Analog Media Module)<br />

● MG-IAMM (Integrated Analog Media Module)<br />

2 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1513