Communication Manager Maintenance Object Repair Procedures<br />

Table 533: FIBER-LK Configuration Audit (#759) 3 of 9<br />

Error<br />

Code<br />

102 -<br />

109,<br />

113 -<br />

120<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The SNI circuit pack cannot communicate with the SNI in a different slot.<br />

1. Perform the Fiber link fault isolation procedures described in Chapter<br />

4: General troubleshooting in Maintenance Procedures (03-300432).<br />

This should resolve multiple SNI-PEER errors.<br />

2. Determine the slot number of the other SNI: Subtract 100 from the<br />

Error Code. For example, if the Error Code is 107, the SNI slot<br />

number is 7. This number is referred to as the "specified SNI slot".<br />

See Table 530: SNI Slot / Error Type to determine the Error Type for<br />

SNI-PEER errors for this specified SNI slot. For example, for SNI slot<br />

9, the Error Type is 1793.<br />

3. If the SNI being tested has SNI-PEER errors of the Error Type<br />

specified in Step 2, replace the SNI being tested. Replacing an SNI<br />

may be service interrupting. Refer to SNI-BD (SNI Circuit Pack) for the<br />

procedure to replace an SNI. To view SNI-PEER errors, enter<br />

display errors with category PNC-PEER. Retry the command.<br />

4. If the SNI being tested still has SNI-PEER errors of the specified Error<br />

Type, replace the SNI in the specified SNI slot.<br />

112 FAIL The SNI circuit pack cannot communicate with the active SNC.<br />

1. Enter list fiber-link to see a fiber link’s endpoints.<br />

2. Check the error log for other SNI circuit packs in the same carrier with<br />

an SNI-BD error with Error Type 257. Enter display errors with<br />

category PNC to view SNI-BD errors. If other SNI circuit packs in the<br />

same switch node carrier have Error 257, replace the active SNC in<br />

this switch node carrier. Replacing an SNC may be service<br />

interrupting. Refer to SNC-BD (Switch Node Clock Circuit Pack) for<br />

the procedure for replacing an SNC.<br />

3. Replace this SNI. Refer to SNI-BD (SNI Circuit Pack) for the<br />

procedure.<br />

4. Replace the active SNC in the same switch node carrier.<br />

1812 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />