Table 347: SYSTEM Error Log Entries 2 of 2<br />

Error<br />

Type<br />

602 (i)<br />

603 (j)<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended<br />

Action<br />

SYSTEM (System)<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: run the Short Test Sequence first. If all tests pass, run the Long Test<br />

Sequence. Refer to the appropriate test description and follow the recommended<br />

procedures.<br />

b. Error Type 8: a System Restart Level 3 was requested.<br />

c. Error Type 9: a System Restart Level 2 was requested. This can happen due to a loss of<br />

tones (due to a faulty Tone-Clock circuit pack).<br />

d. Error Type 10: a System Restart Level 1 was requested.<br />

e. Error Type 21: a process trapped.<br />

f. Error Type 355: a Restart Level 2 occurred due to a power loss.<br />

g. Error Type 356: a Restart Level 2 occurred due to a tone clock loss.<br />

h. Error Type 601: an error occurred during initialization.<br />

i. Error Type 602: an error occurred while loading translations and the system requested a<br />

Restart Level 3.<br />

j. Error Type 603: a process was reset.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1293