Table 535: SNI-BD Configuration Audit (#759) 3 of 6<br />

Error<br />

Code<br />

102 -<br />

109,<br />

113-<br />

120<br />

Test<br />

Result<br />

Description / Recommendation<br />

Configuration Audit (#759)<br />

FAIL The SNI circuit pack cannot communicate with the SNI in a different slot.<br />

1. Determine the slot number of the other SNI: Subtract 100 from the<br />

Error Code. For example, if the Error Code is 107, the SNI slot<br />

number is 7. This number is referred to as the "specified SNI slot".<br />

2. Perform the Fiber link fault isolation procedure in Maintenance<br />

Procedures (03-300432). This will resolve multiple SNI-PEER errors.<br />

3. See Table 530: SNI Slot / Error Type to determine the Error Type for<br />

SNI-PEER errors. For example, if the specified SNI slot is 9, the Error<br />

Type is 1793. If the SNI being tested has SNI-PEER errors of the<br />

specified Error Type, replace the SNI being tested. Replacing an SNI<br />

may be service interrupting. See SNI-BD (SNI Circuit Pack) for the<br />

procedure for replacing an SNI. To view SNI-PEER errors, enter<br />

display errors with category PNC-PEER. Retry the command.<br />

4. If the SNI being tested has SNI-PEER errors of the specified Error<br />

Type, replace the SNI in the specified SNI slot. Retry the command.<br />

112 FAIL The SNI circuit pack cannot communicate with the active SNC.<br />

1. Check the error log for other SNI circuit packs in the same carrier with<br />

a 257 SNI-BD error. Enter display errors with category PNC to<br />

view SNI-BD errors. If other SNI circuit packs in the same switch node<br />

carrier have error 257, then replace the active SNC in this switch node<br />

carrier. Replacing an SNC may be service interrupting. See SNC-BD<br />

(Switch Node Clock Circuit Pack) for the procedure for replacing an<br />

SNC. If other SNI circuit packs in the same carrier do not have<br />

SNI-BD Error Type 257 logged, proceed to step 2.<br />

2. Replace this SNI. Replacing an SNI may be service interrupting. See<br />

SNI-BD (SNI Circuit Pack) for the procedure for replacing an SNI.<br />

3. Replace the active SNC in the same switch node carrier. Replacing an<br />

SNC may be service interrupting. See SNC-BD (Switch Node Clock<br />

Circuit Pack) for the procedure for replacing an SNC.<br />

133 FAIL No neighbor link is administered, but the SNI has an EI neighbor.<br />

1. Administer the SNI on a fiber link to the EI neighbor it is connected to<br />

using add fiber-link next. Or remove both fiber endpoints (i.e.,<br />

this SNI and its EI neighbor) and remove the fiber endpoints from<br />

circuit pack administration using change circuit-pack.<br />

3 of 6<br />

Communication Manager Release 5.0 Issue 4 January 2008 1825