Table 114: AN-LN-PT Error log entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

257 (e) 40973 None<br />

Associated Test Alarm<br />

Level<br />

AN-LN-PT (Analog Line Port)<br />

513 (f) Ringing Application Test (#48) WRN OFF test port location r 2<br />

769 Port Diagnostic Test (#35) MIN<br />

WRN 1<br />

1025 Looparound test (#161) MIN<br />

WRN2<br />

1281 Conference Circuit Test (#7) MIN<br />

WRN2<br />

1537 NPE Crosstalk Test (#6) MIN<br />

WRN2<br />

On/Off<br />

Board<br />

Recommended Action<br />

ON test port location r 2<br />

ON test port location l r 2<br />

ON test port location l r 2<br />

ON test port location l r 2<br />

1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set<br />

options.<br />

Notes:<br />

a. Error type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 1: these are inline errors and can only be resolved over time.<br />

2 of 2<br />

● Aux Data 40960 indicates that too many simultaneous incoming ringing attempts were<br />

made on this board. Only 4 ports on a board may ring simultaneously. A 5 th incoming call<br />

causes an inline error from the board.<br />

● Aux Data 40975 indicates that the terminal equipment was on-hook when ring-tip was<br />

detected during ringing. This usually indicates a failure in the terminal equipment or the<br />

type of terminal has a low ringer impedance.<br />

1. Call the terminal equipment and verify that the terminal rings.<br />

2. If the terminal does not ring, replace it. Otherwise, run test port location, and<br />

follow the procedure for ONS Ringer Application Test (#48).<br />

● Aux Data 40977 indicates that no terminal equipment was connected when ringing was<br />

attempted. Run test port location, and follow the procedure for the results of ONS<br />

Ringer Application Test (#48).<br />

c. Error Type 15: software audit error that does not indicate any hardware malfunction. Run<br />

the short test sequence, and investigate any associated errors.<br />

d. Error Type 130: the circuit pack or media module has been removed or has been insane for<br />

more than 11 minutes. To clear the error, reseat or replace the circuit pack or media module.<br />

Communication Manager Release 5.0 Issue 4 January 2008 453